HVAC Delta T Calculator (Temperature Split)
Check your AC or furnace temperature split — the delta T between return and supply air — whether it's in the normal range, and the…
Check your AC or furnace temperature split — the delta T between return and supply air — whether it's in the normal range, and the BTU/hr it represents at your airflow.
Results
About This Calculator
Measure at the return grille and the supply register closest to the air handler after the system has run 10–15 minutes. Humid days lower the cooling split; the furnace rise range is printed on its data plate.
Example
Example: 75 °F return and 57 °F supply air is an 18 °F split — normal range.
Assumptions
Normal cooling split ≈ 16–22 °F; furnace rise ≈ 30–70 °F. Sensible BTU/hr = 1.08 × cfm × ΔT.
Frequently Asked Questions
What should the AC temperature difference be?
About 16–22 °F between return and supply air.