HVAC Delta T Calculator (Temperature Split)

Check your AC or furnace temperature split — the delta T between return and supply air — whether it's in the normal range, and the…

Results

Enter your details and click Calculate to see your results.
About This Calculator

Measure at the return grille and the supply register closest to the air handler after the system has run 10–15 minutes. Humid days lower the cooling split; the furnace rise range is printed on its data plate.

Example

Example: 75 °F return and 57 °F supply air is an 18 °F split — normal range.

Assumptions

Normal cooling split ≈ 16–22 °F; furnace rise ≈ 30–70 °F. Sensible BTU/hr = 1.08 × cfm × ΔT.

Frequently Asked Questions

What should the AC temperature difference be?

About 16–22 °F between return and supply air.