Electrical Load Calculator (Service Size)

Calculate a home's electrical load with the NEC 220.82 optional method — general lighting, small-appliance and laundry circuits, appliances and HVAC — and the service…

Results

Enter your details and click Calculate to see your results.
About This Calculator

Enter the living area and the nameplate VA of fixed appliances. Use the larger of heating or cooling — the method only counts one.

Example

Example: a 2,400 sq ft all-electric-kitchen home with an EV charger calculates to 30,520 VA — 127.17 A at 240 V, so a 150 A service.

Assumptions

NEC 220.82: 3 VA per sq ft + 1,500 VA per small-appliance and laundry circuit + appliances; first 10 kVA at 100% and the rest at 40%; plus 100% of the larger HVAC load. Load calcs for permits must be done to your adopted code edition. Results are engineering and budgeting estimates — electrical work must follow the NEC and local code and be designed or checked by a licensed professional, and energy prices and incentives change.

Frequently Asked Questions

Do I need a 200 amp service?

Most modern homes with central AC, an electric range or an EV charger calculate between 100 and 200 A; 200 A is the common choice.

Related Calculators