Fire Code Occupancy Calculator
Calculate the maximum occupancy (occupant load) of a room or building from its floor area and use, using IBC / IFC occupant load factors, plus…
Calculate the maximum occupancy (occupant load) of a room or building from its floor area and use, using IBC / IFC occupant load factors, plus exits needed.
Results
About This Calculator
Measure the floor area. 'Net' areas exclude walls, corridors, restrooms and fixed equipment; 'gross' areas include them.
Example
Example: a 2,000 sq ft banquet room with tables and chairs (15 sq ft net per person) holds 133 people and needs 2 exits.
Assumptions
IBC / IFC Table 1004.5 occupant load factors; exits per IBC 1006.3 (2 exits above 49 occupants, 3 above 500, 4 above 1,000); exit width 0.2 inch per occupant (sprinklered buildings may use 0.15). Your fire marshal sets the posted capacity, and state amendments (e.g. North Carolina) may differ. This is an estimate — government fees, tax rates and pay tables change, so confirm with the agency before you pay or plan.
Frequently Asked Questions
How is maximum occupancy calculated?
Floor area divided by the occupant load factor for the space's use — for example 15 sq ft per person for tables and chairs.
What is the occupancy for a 1,000 sq ft room?
About 142 people standing-room chairs-only (7 sq ft each), 66 at tables, or 6–7 in office use (150 sq ft each).