Steel Column Capacity Calculator
Calculate the axial design strength of a steel column with the AISC flexural buckling equations.
Calculate the axial design strength of a steel column with the AISC flexural buckling equations.
Results
Enter your details and click Calculate to see your results.
About This Calculator
Fe = π²E/(KL/r)²; Fcr = 0.658^(Fy/Fe)·Fy or 0.877Fe; φPn = 0.9·Fcr·Ag.
Example
Example: the default inputs → Design Strength: φPn ≈ 283.34 kips.
Assumptions
Preliminary engineering check only — a licensed engineer must design and approve real structures and pressure equipment.
Frequently Asked Questions
What is slenderness ratio?
KL/r — higher means more prone to buckling.
Which axis controls?
Usually the weak axis (smallest r).