Tolerance Stack-Up Calculator (Worst Case & RSS)

Add up a chain of dimensions and their ± tolerances to get the nominal gap, the worst-case range and the statistical root-sum-square (RSS) range. Shows…

Results

Enter your details and click Calculate to see your results.
About This Calculator

Walk round the loop from one side of the gap to the other. Dimensions that increase the gap are +, ones that reduce it are −. Worst case adds every tolerance, so every part is assumed at its limit at the same time. RSS assumes the variations are random and independent, so they partly cancel: ±√(t₁² + t₂² + …).

Use worst case for safety-critical or low-volume parts, and RSS for high-volume production with capable processes.

Example

Example: a 50 ±0.1 housing holding parts of 20 ±0.05 and 29.8 ±0.08 leaves a nominal gap of 0.2. Worst case -0.03 to 0.43 (±0.23); RSS 0.0625227 to 0.337477 (±0.1375).

Assumptions

RSS treats each tolerance as ±3σ of a centred normal distribution. Geometric tolerances (position, flatness) need converting into equivalent ± values first.