Wall Assembly R-Value Calculator (With Framing)

Calculate the effective R-value of a framed wall assembly using the parallel path method, including framing and continuous insulation.

Results

Enter your details and click Calculate to see your results.
About This Calculator

Parallel path: U = (1 − f) ÷ R_cavity path + f ÷ R_stud path, where f is the framing fraction. Wood studs (R-1.25/in) bridge the cavity; steel studs need the zone method or a correction factor instead.

Example

Example: 2×4 R-13 wall with R-7.5 exterior insulation → Effective R-Value: R-19.3 effective assembly.

Assumptions

For wood framing. Steel studs perform much worse.

Frequently Asked Questions

Why is effective R lower than R-13?

Studs conduct heat through the insulation.

What framing fraction?

About 25% for 16 in o.c. walls.

Related Calculators