Valve Cv Calculator (Flow Coefficient for Liquid & Gas)

Calculate a valve's flow coefficient (Cv) from liquid flow in gpm, pressure drop and specific gravity, find the flow for a given Cv, or size…

Results

Enter your details and click Calculate to see your results.
About This Calculator

Liquid: Cv = Q × √(SG ÷ ΔP), where Q is US gallons per minute and ΔP is in psi. Cv is the gpm of water that flows with a 1 psi drop.

Gas (Swagelok, non-choked): Q = 22.67 × Cv × P₁ × (1 − 2ΔP ÷ 3P₁) × √(ΔP ÷ (P₁ × SG × T₁)), with P₁ in psia and T₁ in °R. Kv = 0.865 × Cv.

Example

Example: 10 gpm of water with a 10 psi drop needs a valve with Cv = 3.162 (Kv = 2.735 (m³/h at 1 bar)).

Assumptions

Turbulent, non-flashing, non-choked flow.

Frequently Asked Questions

What does Cv mean?

Gallons per minute of 60 °F water through the valve with a 1 psi pressure drop.

How do you convert Cv to Kv?

Kv = 0.865 × Cv.

How do I size a valve?

Calculate the required Cv and pick a valve with a rated Cv about 20–50% higher.