Coplanar Waveguide (CPW / CPWG) Impedance Calculator

Calculate the characteristic impedance and effective εr of a coplanar waveguide, with or without a bottom ground plane (CPWG).

Results

Enter your details and click Calculate to see your results.
About This Calculator

Conformal mapping with complete elliptic integrals K(k), k = w/(w + 2s); grounded CPW adds the bottom-ground term with k₃ = tanh(πw/4h)/tanh(π(w + 2s)/4h).

Example

Example: 1 mm trace, 0.2 mm gaps on 1.6 mm FR-4, grounded → 54.3758 Ω.

Assumptions

Zero-thickness conductors, wide side grounds, plenty of stitching vias.

Frequently Asked Questions

Why CPWG?

Low radiation and easy grounding of components at RF.

Related Calculators

About the Author

Imran Hossain
Imran Hossain

Professional SEO, Digital Marketer Specialist

I am a Certified Google Ads Expert And Professional SEO, Digital Marketing Specialist

View full profile