Noise Figure Calculator (Cascaded Friis NF & Noise Temperature)
Work out the total noise figure, noise temperature and gain of a receiver chain from each stage's gain and noise figure (Friis formula). Also gives…
Work out the total noise figure, noise temperature and gain of a receiver chain from each stage's gain and noise figure (Friis formula). Also gives the noise floor and receiver sensitivity for a bandwidth and required SNR.
Results
About This Calculator
Friis' formula: F = F₁ + (F₂ − 1)/G₁ + (F₃ − 1)/(G₁G₂) + …, using linear values. Each later stage's noise is divided by the gain in front of it, which is why a low-noise amplifier goes first.
A passive loss (filter, cable) has gain = −loss and NF = loss. Noise temperature Te = 290 K × (F − 1).
Example
Example: an LNA (20 dB, 1.5 dB NF), then a mixer (10 dB, 6 dB NF) and a 3 dB filter, gives a cascaded NF of 1.594 dB. Sensitivity in 1 MHz is -102.4 dBm.
Assumptions
Stages are matched (no mismatch loss) and the source is at 290 K. Sensitivity = −174 dBm/Hz + 10·log₁₀(BW) + NF + SNR.
Frequently Asked Questions
Why put the LNA first?
Its gain divides the noise of every stage after it, so the first stage's NF dominates the total.
What is the noise figure of a cable?
Equal to its loss: a 3 dB cable has NF = 3 dB.
Related Calculators
About the Author

Professional SEO, Digital Marketer Specialist
I am a Certified Google Ads Expert And Professional SEO, Digital Marketing Specialist
View full profile