PCB Via Calculator (Current, Resistance & Inductance)
Calculate a plated through-hole via's current capacity for a temperature rise, plus its resistance, voltage drop, inductance, capacitance and thermal resistance, from the drill size,…
Calculate a plated through-hole via's current capacity for a temperature rise, plus its resistance, voltage drop, inductance, capacitance and thermal resistance, from the drill size, plating and board thickness.
Results
About This Calculator
Current flows through the copper plated on the hole wall, which is a thin tube. Its cross-section is π × (d + t) × t. Current capacity uses the IPC-2221 external-conductor formula on that area.
For high currents, use several vias in parallel: each one carries its share, and the inductance drops too.
Example
Example: a 0.3 mm via with 25 µm plating in a 1.6 mm board carries about 1.9 A for a 10 °C rise, with 1.144 mΩ resistance and 1.299 nH inductance.
Assumptions
Copper resistivity 1.724 µΩ·cm at 20 °C. The IPC-2221 trace formula is a conservative estimate for vias (IPC-2152 data allow more). Inductance and capacitance use the standard Howard Johnson approximations.
Frequently Asked Questions
How much current can a via carry?
A standard 0.3 mm via in a 1.6 mm board carries about 1.5–2 A for a 10 °C rise.
Does via inductance matter?
Yes, at high frequencies. About 1 nH per via affects decoupling and high-speed signals.