Thermocouple Calculator (Type K, J & T mV ↔ °C)

Convert a thermocouple's millivolt output to temperature, or temperature to millivolts, for type K, J and T using the NIST ITS-90 reference functions. Includes cold-junction…

Results

Enter your details and click Calculate to see your results.
About This Calculator

A thermocouple produces a voltage from the temperature difference between its hot tip and the cold junction, where it connects to the meter. Reference tables assume a cold junction at 0 °C. If the terminals are at room temperature, enter that and the calculator adds the cold-junction voltage back.

Type K is the general-purpose choice up to 1,260 °C. Type J suits reducing atmospheres. Type T is accurate at low temperatures.

Example

Example: 4.096 mV from a type K thermocouple with its cold junction at 0 °C means 99.99 °C.

Assumptions

NIST ITS-90 reference functions for standard-grade wire (type K ±2.2 °C or 0.75%). The inverse is solved numerically.

Frequently Asked Questions

What voltage is a type K thermocouple at 100 °C?

4.096 mV with the cold junction at 0 °C.

What is cold-junction compensation?

Adding the voltage the cold junction would produce at its real temperature, so the reading matches the 0 °C tables.