Transmission Line Impedance Calculator (Coax & Twin-Lead)

Calculate characteristic impedance, velocity factor, capacitance and inductance per metre of coax or twin-lead — or the antenna far-field distance.

Results

Enter your details and click Calculate to see your results.
About This Calculator

Coax: Z₀ = (60/√εr)·ln(D/d). Twin-lead: Z₀ = (120/√εr)·acosh(D/d). VF = 1/√εr. Far field ≥ 2D²/λ.

Example

Example: 7.25/2.17 mm, PE dielectric → 48.251 Ω.

Assumptions

Lossless line; D/d dimensions are inner diameter of the shield and centre conductor.

Frequently Asked Questions

Why 50 Ω?

A compromise between lowest loss (77 Ω) and highest power handling (30 Ω).