Transmission Line Impedance Calculator (Coax & Twin-Lead)
Calculate characteristic impedance, velocity factor, capacitance and inductance per metre of coax or twin-lead — or the antenna far-field distance.
Calculate characteristic impedance, velocity factor, capacitance and inductance per metre of coax or twin-lead — or the antenna far-field distance.
Results
Enter your details and click Calculate to see your results.
About This Calculator
Coax: Z₀ = (60/√εr)·ln(D/d). Twin-lead: Z₀ = (120/√εr)·acosh(D/d). VF = 1/√εr. Far field ≥ 2D²/λ.
Example
Example: 7.25/2.17 mm, PE dielectric → 48.251 Ω.
Assumptions
Lossless line; D/d dimensions are inner diameter of the shield and centre conductor.
Frequently Asked Questions
Why 50 Ω?
A compromise between lowest loss (77 Ω) and highest power handling (30 Ω).